{"id":6818,"date":"2020-06-19T16:22:05","date_gmt":"2020-06-19T10:52:05","guid":{"rendered":"https:\/\/nuclearrambo.com\/wordpress\/?p=6818"},"modified":"2024-10-03T15:14:35","modified_gmt":"2024-10-03T09:44:35","slug":"alarm-system-wiring-dyi","status":"publish","type":"post","link":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/","title":{"rendered":"Alarm system wiring &#8211; DYI &#8211; Paradox Wiring"},"content":{"rendered":"\n<p>The wiring process of an alarm system is the trickiest one. Everything else is easy, but wiring is what makes it hard. I was forced to learn to install alarm systems my own way and using guides as well. Alarm systems are necessary to prevent burglars from coming in. Nowadays, surveillance CCTV cameras are not enough to prevent a burglar from going inside your home. But how to actually get such alarm system? It would be easy to hire an alarm system technician to come and install an alarm system for your house. But what if you wanted to DYI? What are the steps in order to do an efficient alarm system wiring and what components are compulsory. It is not an easy task, but i am doing my best to explain.<\/p>\n\n\n\n<p>I am taking Paradox SP5500 alarm system as an example for the installation and wiring process.<\/p>\n\n\n\n<center><p><script type=\"text\/javascript\">\n\tatOptions = {\n\t\t'key' : 'a488f095e80c8a74746e5fdca977eaea',\n\t\t'format' : 'iframe',\n\t\t'height' : 90,\n\t\t'width' : 728,\n\t\t'params' : {}\n\t};\n\tdocument.write('<scr' + 'ipt type=\"text\/javascript\" src=\"http' + (location.protocol === 'https:' ? 's' : '') + ':\/\/www.profitabledisplaynetwork.com\/a488f095e80c8a74746e5fdca977eaea\/invoke.js\"><\/scr' + 'ipt>');\n<\/script><\/p><\/center>\n\n\n\n<h2 class=\"wp-block-heading\">Preparing the components<\/h2>\n\n\n\n<p>Before doing anything, make sure that all the compulsory components are in the package. Optional components are useful too, so if you have those as well, great!<\/p>\n\n\n\n<p><strong>Compulsory components are:<\/strong><\/p>\n\n\n\n<p>-Special metal box for alarm system;<\/p>\n\n\n\n<p>-Alarm system panel;<\/p>\n\n\n\n<p>-Pir sensors;<\/p>\n\n\n\n<p>-Siren;<\/p>\n\n\n\n<p>-Keypad;<\/p>\n\n\n\n<p>-UPS \/ AVR;<\/p>\n\n\n\n<p>-2 batteries 4Ah (7Ah) 12V DC;<\/p>\n\n\n\n<p>Optional components are:<\/p>\n\n\n\n<p>-RTX 3;<\/p>\n\n\n\n<p>-Magnets;<\/p>\n\n\n\n<p>-PCS 250, PCS 250G;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Installing the components and wiring<\/h2>\n\n\n\n<p>I won\u2019t go too deep in the installing process. There is a more comprehensive article written <a href=\"https:\/\/nuclearrambo.com\/wordpress\/how-to-install-an-alarm-system-paradox-sp5500\/\">here<\/a> about everything that needs to be done. I will concentrate more on the wiring process.<\/p>\n\n\n\n<p>The most important thing to remember is to cut off power to the panel by turning off the fuse switch. And then take out the fuse from the SP5500 panel.<\/p>\n\n\n\n<p><strong>SIREN;<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><span style=\"color: #ff0000;\"><strong>RED<\/strong><\/span>, <strong>BLACK<\/strong>, <span style=\"color: #00ccff;\"><strong>T<\/strong><strong style=\"font-family: 'Open Sans', sans-serif; font-size: 18px; font-style: normal;\">AMPER<\/strong><\/span>, <span style=\"color: #993366;\"><strong>TAMPER<\/strong><\/span>, <strong>START 2<\/strong>;<\/li>\n<\/ul>\n\n\n\n<p><strong>PIR MOTION SENSOR;<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong><span style=\"color: #ff9900;\">NC<\/span>, COM (resistor<span style=\"color: #339966;\"> 1K<\/span>, <span style=\"color: #ff0000;\">2K<\/span> to TAMPER), <span style=\"color: #ff0000;\">RED<\/span>, BLACK, TAMPER (resistor <span style=\"color: #339966;\">1K<\/span>, <span style=\"color: #ff0000;\">2K<\/span> to COM), \u00a0<span style=\"color: #339966;\">TAMPER<\/span>;<\/strong><\/li>\n<\/ul>\n\n\n\n<p><strong>KEYPAD;<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><span style=\"color: #ff0000;\"><strong>RED<\/strong><\/span>, <strong>BLACK<\/strong>, <strong><span style=\"color: #00ff00;\">GREEN<\/span>, <span style=\"color: #ff9900;\">YELLOW<\/span>;<\/strong><\/li>\n<\/ul>\n\n\n\n<p><strong>RTX 3;<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><span style=\"color: #ff0000;\"><strong>RED<\/strong><\/span>, <strong>BLACK<\/strong>, <strong><span style=\"color: #00ff00;\">GREEN<\/span>, <span style=\"color: #ff9900;\">YELLOW<\/span>;<\/strong><\/li>\n<\/ul>\n\n\n\n<p><strong>SMOKE DETECTOR;<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><span style=\"color: #ff0000;\"><strong>RED<\/strong><\/span>, <strong>BLACK<\/strong>, <strong><span style=\"color: #ff9900;\">NC<\/span>, <span style=\"color: #339966;\">TAMPER<\/span>;<\/strong><\/li>\n<\/ul>\n\n\n\n<p>It\u2019s important that you use resistors to identify if it\u2019s parallel zoning or not.<\/p>\n\n\n\n<p>Do not forget to write with a marker on each specific wire that goes to the panel. Otherwise it will be hard to identify which is what.<\/p>\n\n\n\n<center><p><script type=\"text\/javascript\">\n\tatOptions = {\n\t\t'key' : 'a488f095e80c8a74746e5fdca977eaea',\n\t\t'format' : 'iframe',\n\t\t'height' : 90,\n\t\t'width' : 728,\n\t\t'params' : {}\n\t};\n\tdocument.write('<scr' + 'ipt type=\"text\/javascript\" src=\"http' + (location.protocol === 'https:' ? 's' : '') + ':\/\/www.profitabledisplaynetwork.com\/a488f095e80c8a74746e5fdca977eaea\/invoke.js\"><\/scr' + 'ipt>');\n<\/script><\/p><\/center>\n\n\n\n<h2 class=\"wp-block-heading\">Wiring main box and panel<\/h2>\n\n\n\n<p>Main box contains a transformer which needs to be wired to the main power.<\/p>\n\n\n\n<p>From the transformer you need to use the AC wires to power up the panel.<\/p>\n\n\n\n<p>Cut the brown wire as you only need yellow and blue wires.<\/p>\n\n\n\n<p>Connect the earthing wire in the panel where it shows the earth ground symbol<\/p>\n\n\n\n<p>Then start connecting the wires for each component:<\/p>\n\n\n\n<p><strong>Siren:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><span style=\"color: #ff0000;\"><strong>RED<\/strong><\/span>, <strong>BLACK<\/strong>, <span style=\"color: #339966;\"><strong>Z1<\/strong> (<strong>TAMPER<\/strong>)<\/span>, <strong><span style=\"color: #339966;\">COM (TAMPER)<\/span>, <\/strong>BELL \u2013 and + <strong><span style=\"color: #339966;\">(START 2)<\/span>;<\/strong> for SP5500, the green wire goes to \u2013 on the BELL using a resistor.<\/li>\n<\/ul>\n\n\n\n<p>It doesn\u2019t have to be Z1, it can be any zone you wish. But it\u2019s important that you use resistors to identify if it\u2019s parallel zoning or not.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/SIREN-BELL-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/SIREN-BELL-1024x768.jpg\" alt=\"SIREN BELL\" class=\"wp-image-6823\" srcset=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/SIREN-BELL-1024x768.jpg 1024w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/SIREN-BELL-300x225.jpg 300w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/SIREN-BELL-768x576.jpg 768w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/SIREN-BELL-1536x1152.jpg 1536w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/SIREN-BELL-2048x1536.jpg 2048w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/SIREN-BELL-600x450.jpg 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p><strong>Pir motion sensor:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong><span style=\"color: #ff9900;\">Z1 (NC)<\/span>,<\/strong> <span style=\"color: #ff0000;\"><strong>RED<\/strong><\/span>, <strong>BLACK<\/strong>, <span style=\"color: #339966;\"><strong>COM (TAMPER)<\/strong><\/span><\/li>\n<\/ul>\n\n\n\n<p><strong>The keypad and the RTX 3:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><span style=\"color: #ff0000;\"><strong>RED<\/strong><\/span>, <strong>BLACK,<\/strong> <strong><span style=\"color: #00ff00;\">GREEN<\/span>,<span style=\"color: #ff9900;\"> YELLOW<\/span><\/strong><\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/red-black-green-yellow-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/red-black-green-yellow-1024x768.jpg\" alt=\"red black green yellow\" class=\"wp-image-6824\" srcset=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/red-black-green-yellow-1024x768.jpg 1024w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/red-black-green-yellow-300x225.jpg 300w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/red-black-green-yellow-768x576.jpg 768w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/red-black-green-yellow-1536x1152.jpg 1536w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/red-black-green-yellow-2048x1536.jpg 2048w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/red-black-green-yellow-600x450.jpg 600w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<p><strong>Smoke detector:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><span style=\"color: #ff0000;\"><strong>RED<\/strong><\/span>, <strong>BLACK,<\/strong> <strong><span style=\"color: #ff9900;\">Z1 (NC)<\/span>,<\/strong> \u00a0<span style=\"color: #339966;\"><strong>COM (TAMPER)<\/strong><\/span><\/li>\n<\/ul>\n\n\n\n<p>The complete wiring diagram of components, main box and the panel:<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system-1024x576.png\" alt=\"Alarm system\" class=\"wp-image-6825\" srcset=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system-1024x576.png 1024w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system-300x169.png 300w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system-768x432.png 768w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system-1536x864.png 1536w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system-600x338.png 600w, https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Starting up the alarm system<\/h2>\n\n\n\n<p>Check that everything is in place. This is the most important step to do after you have done the wiring process. Proceed on wiring one battery to the siren and then connect the other battery to the SP5500 board. Make sure you do it in the order that i mentioned. Turn on the fuse switch for the main power and then put the fuse for the control panel back in its place. The programming phase is described better in <a href=\"https:\/\/nuclearrambo.com\/wordpress\/how-to-install-an-alarm-system-paradox-sp5500\/\">this article<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The wiring process of an alarm system is the trickiest one. Everything else is easy, but wiring is what makes it hard. I was forced to learn to install alarm systems my own way&#46;&#46;&#46;<\/p>\n","protected":false},"author":36791,"featured_media":6828,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1672],"tags":[1681],"class_list":["post-6818","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-home-security-and-networking","tag-alarm-system"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v20.5 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Alarm system wiring - DYI - Paradox Wiring<\/title>\n<meta name=\"description\" content=\"How to DYI the alarm system wiring process in order to install your own alarm system? In this article i am going to explain how to do that.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Alarm system wiring - DYI - Paradox Wiring\" \/>\n<meta property=\"og:description\" content=\"How to DYI the alarm system wiring process in order to install your own alarm system? In this article i am going to explain how to do that.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/\" \/>\n<meta property=\"og:site_name\" content=\"Nuclearrambo\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-19T10:52:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-10-03T09:44:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system-wiring.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"nuclearrambo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@darkusul\" \/>\n<meta name=\"twitter:site\" content=\"@darkusul\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"nuclearrambo\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/\"},\"author\":{\"name\":\"nuclearrambo\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/person\/fec44a2d06507e372c4b2881afa9ecf1\"},\"headline\":\"Alarm system wiring &#8211; DYI &#8211; Paradox Wiring\",\"datePublished\":\"2020-06-19T10:52:05+00:00\",\"dateModified\":\"2024-10-03T09:44:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/\"},\"wordCount\":616,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#organization\"},\"keywords\":[\"alarm system\"],\"articleSection\":[\"Home security and Networking\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/\",\"url\":\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/\",\"name\":\"Alarm system wiring - DYI - Paradox Wiring\",\"isPartOf\":{\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#website\"},\"datePublished\":\"2020-06-19T10:52:05+00:00\",\"dateModified\":\"2024-10-03T09:44:35+00:00\",\"description\":\"How to DYI the alarm system wiring process in order to install your own alarm system? In this article i am going to explain how to do that.\",\"breadcrumb\":{\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/nuclearrambo.com\/wordpress\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Alarm system wiring &#8211; DYI &#8211; Paradox Wiring\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#website\",\"url\":\"https:\/\/nuclearrambo.com\/wordpress\/\",\"name\":\"Nuclearrambo\",\"description\":\"Information is FREE! Progress is MUST! Awakening is inevitable!\",\"publisher\":{\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/nuclearrambo.com\/wordpress\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#organization\",\"name\":\"Nuclearrambo\",\"url\":\"https:\/\/nuclearrambo.com\/wordpress\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2021\/01\/logo-nuclearrambo.png\",\"contentUrl\":\"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2021\/01\/logo-nuclearrambo.png\",\"width\":1489,\"height\":1152,\"caption\":\"Nuclearrambo\"},\"image\":{\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/twitter.com\/darkusul\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/person\/fec44a2d06507e372c4b2881afa9ecf1\",\"name\":\"nuclearrambo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/79bb913f669e9930a954234757f7e659eaa773f2c00f18a13afead8483d93e9b?s=96&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/79bb913f669e9930a954234757f7e659eaa773f2c00f18a13afead8483d93e9b?s=96&r=g\",\"caption\":\"nuclearrambo\"},\"description\":\"As a person that feels intrigued by technology, lots of opportunities that came in my way opened my eyes for a better view of the future. I cherish the times we live in! There is no better time but now to learn as much as we can, and share it with the world. I am currently working with surveillance and networking systems, other related IT things too. I am looking forward to write amazing content for our readers.\",\"sameAs\":[\"http:\/\/nuclearrambo.com\/wordpress\"],\"url\":\"https:\/\/nuclearrambo.com\/wordpress\/author\/alin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Alarm system wiring - DYI - Paradox Wiring","description":"How to DYI the alarm system wiring process in order to install your own alarm system? In this article i am going to explain how to do that.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/","og_locale":"en_US","og_type":"article","og_title":"Alarm system wiring - DYI - Paradox Wiring","og_description":"How to DYI the alarm system wiring process in order to install your own alarm system? In this article i am going to explain how to do that.","og_url":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/","og_site_name":"Nuclearrambo","article_published_time":"2020-06-19T10:52:05+00:00","article_modified_time":"2024-10-03T09:44:35+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2020\/06\/Alarm-system-wiring.jpg","type":"image\/jpeg"}],"author":"nuclearrambo","twitter_card":"summary_large_image","twitter_creator":"@darkusul","twitter_site":"@darkusul","twitter_misc":{"Written by":"nuclearrambo","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/#article","isPartOf":{"@id":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/"},"author":{"name":"nuclearrambo","@id":"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/person\/fec44a2d06507e372c4b2881afa9ecf1"},"headline":"Alarm system wiring &#8211; DYI &#8211; Paradox Wiring","datePublished":"2020-06-19T10:52:05+00:00","dateModified":"2024-10-03T09:44:35+00:00","mainEntityOfPage":{"@id":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/"},"wordCount":616,"commentCount":0,"publisher":{"@id":"https:\/\/nuclearrambo.com\/wordpress\/#organization"},"keywords":["alarm system"],"articleSection":["Home security and Networking"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/","url":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/","name":"Alarm system wiring - DYI - Paradox Wiring","isPartOf":{"@id":"https:\/\/nuclearrambo.com\/wordpress\/#website"},"datePublished":"2020-06-19T10:52:05+00:00","dateModified":"2024-10-03T09:44:35+00:00","description":"How to DYI the alarm system wiring process in order to install your own alarm system? In this article i am going to explain how to do that.","breadcrumb":{"@id":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/nuclearrambo.com\/wordpress\/alarm-system-wiring-dyi\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/nuclearrambo.com\/wordpress\/"},{"@type":"ListItem","position":2,"name":"Alarm system wiring &#8211; DYI &#8211; Paradox Wiring"}]},{"@type":"WebSite","@id":"https:\/\/nuclearrambo.com\/wordpress\/#website","url":"https:\/\/nuclearrambo.com\/wordpress\/","name":"Nuclearrambo","description":"Information is FREE! Progress is MUST! Awakening is inevitable!","publisher":{"@id":"https:\/\/nuclearrambo.com\/wordpress\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/nuclearrambo.com\/wordpress\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/nuclearrambo.com\/wordpress\/#organization","name":"Nuclearrambo","url":"https:\/\/nuclearrambo.com\/wordpress\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/logo\/image\/","url":"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2021\/01\/logo-nuclearrambo.png","contentUrl":"https:\/\/nuclearrambo.com\/wordpress\/wp-content\/uploads\/2021\/01\/logo-nuclearrambo.png","width":1489,"height":1152,"caption":"Nuclearrambo"},"image":{"@id":"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/twitter.com\/darkusul"]},{"@type":"Person","@id":"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/person\/fec44a2d06507e372c4b2881afa9ecf1","name":"nuclearrambo","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/nuclearrambo.com\/wordpress\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/79bb913f669e9930a954234757f7e659eaa773f2c00f18a13afead8483d93e9b?s=96&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/79bb913f669e9930a954234757f7e659eaa773f2c00f18a13afead8483d93e9b?s=96&r=g","caption":"nuclearrambo"},"description":"As a person that feels intrigued by technology, lots of opportunities that came in my way opened my eyes for a better view of the future. I cherish the times we live in! There is no better time but now to learn as much as we can, and share it with the world. I am currently working with surveillance and networking systems, other related IT things too. I am looking forward to write amazing content for our readers.","sameAs":["http:\/\/nuclearrambo.com\/wordpress"],"url":"https:\/\/nuclearrambo.com\/wordpress\/author\/alin\/"}]}},"_links":{"self":[{"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/posts\/6818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/users\/36791"}],"replies":[{"embeddable":true,"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/comments?post=6818"}],"version-history":[{"count":12,"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/posts\/6818\/revisions"}],"predecessor-version":[{"id":8423,"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/posts\/6818\/revisions\/8423"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/media\/6828"}],"wp:attachment":[{"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/media?parent=6818"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/categories?post=6818"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nuclearrambo.com\/wordpress\/wp-json\/wp\/v2\/tags?post=6818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}